1/24/2024 0 Comments Astrometry website solveI hope that Skipper Billy, you can post the image that you are trying to solve soon as I would like to put that into my system and see what happens.Īs for why doesn't work - good question! Hopefully it won't need an answer though. Perhaps the best thing to do if the Blind Solve with, remote or local, is not satisfying, is to go for a Parially Sighted solve! ![]() So, it seems that fairly close RA & DEC hints are required, but not Angle and Scale hints. I then tried solving with slightly (rather than radically) altered RA & DEC hints, but deleted out the Angle and Scale hints. I am trying out an image at the moment and have changed the RA/DEC/Angle/Scale figures from what it read in from the FITS file header and seeing what happens. You need to put in some starting points for RA, DEC, angle & scale, but hopefully you have enough idea of the image you are using to be able to put something sensible in for that. However, have you tried solving the image with the 'Solve' button rather than 'Blind Solve'? 'Solve' will take the image to PlateSolve2 (or whichever plate solving software solution you have set up). So, no wonder you can't get it to do anything other than that for the Blind Solve option. First thing to note is that Blind Solve will only use and the only options you can select are either the remote version or a local version. ![]() OK, I have just fired up my obsy pc and had a look at my Plate Solve control panel settings. I've done a video showing the process of downloading, installing and running Platesolve2 so will send you the link later today. I use Pinpoint personally as it used to be needed for the F&M wizard (isn't any more) but I downloaded the Pinpoint2 libraries yesterday and ran some tests and it worked fine. I cant even figure out how to fully uninstall SGP so I can try a clean install !!Īs noted by both guys above David it is probably something quite small within settings somewhere so don't lose faith, it really is a very good bit of software. Its driving me nuts!! So annoying - I have got everything else working ! I would love to bin Maxim, Astrtortilla, FocusMax etc but at least they all work !! Spent 10 hours now trying to get this to blind solve to work - I have tried everything I can think of - I cant get SGP to try any programme except ANSVR local then when that fails - remote ANSVR.Įveryone (even the developer of SGP is saying Platesolve2 is the thing to go for but I cant make SGP look at PS2. I suspect this is due to the limiting magnitude of reference catalog data, which appears to be somewhere are 11 or 12 for both Nova and PlateSolve 3. There also seems to be a point where taking longer exposures to bring out fainter stars does little to improve the odds of a successful solution. If you're using a planetary camera in long focal length optical path, plate solution may not be reliable, particularly where sparse fields are involved. I haven't used PlateSolve 2 so I don't know how it compares to PlateSolve 3. This typically occurs only when a very small (< 1 arcmin) field of view is involved or very few stars are present in the image. That said, there are some circumstances where PlateSolve fails to solve a field even given the exact center coordinates and image scale. ![]() Unless things have changed recently with Nova, Dave Rowe's plate solution algorithm is clearly better. PlateSolve is usually somewhat better at blind solving fields (no user-supplied detail regarding coordinates or image scale) and can often solve fields which Nova cannot even when very specific detail is provided. While I have no experience with SGP, I have solved a lot of images using both Nova ( web based tool) and PlateSolve 3.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |